8 – Pump specifications
P
u
mp specificat
ions
HyPrecision 75S
Dimensions and weights
The shipping weight is for the pump, the pallet, and the packaging. Exact weights are taken at shipment.
Operating weight is for an unpackaged pump with hydraulic fluid.
Width
1,016 mm (40 in.)
Shipping weight
1,415 kg (3,120 lb)
Length
1,930 mm (76 in.)
Operating weight
1,497 kg (3,300 lb)
Height
1,422 mm (56 in.)
56 kW, 75 hp
50 Hz
60 Hz
Voltage
400 V
460 V
Full load current
103.0 A
87.1 A
Primary circuit breaker rating
125.0 A
100.0 A
50 Hz
60 Hz
CUTTING WATER IN
Minimum
Maximum
Flow
11.4 L/minute
(3 gallons/minute)
—
Pressure
2.76 bar or 275.79 kPa
(40 psi)
7.93 bar or 792.90 kPa
(115 psi)
CUTTING WATER OUT
Flow
—
5.7 L/minute
(1.49 gallons/minute)
6.1 L/minute
(1.60 gallons/minute)
Pressure
551.58 bar or 55,158 kPa
(8,000 psi)
4,136.85 bar or 413,685 kPa
(60,000 psi)
Continuous pressure
—
4,136.85 bar or 413,685 kPa
(60,000 psi)
Cutting water pressure
factory setpoint
—
4,136.85 bar or 413,685 kPa
(60,000 psi)
Piercing water pressure
factory setpoint
1,38.95 bar or 137,895 kPa
(20,000 psi)
—
COOLING IN and COOLING OUT
Flow
11.4 L/minute
(3 gallons/minute)
—
Pressure
2.76 bar or 275.79 kPa
(40 psi)
7.93 bar or 792.90 kPa
(115 psi)
Summary of Contents for HyPrecision 50S
Page 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Page 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Page 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Page 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...