7 – Troubleshooting
Tr
oubleshooting
An increase in pump temperature can show that there is a problem with the cooling system.
Water-cooled systems
Air-cooled systems
All systems
The cooling water temperature is too high.
• Make sure that the cooling water is turned on.
• Adjust the hydraulic fluid temperature. Refer to page 81
CAUTION
Do not adjust the setting on the thermal overload or the fan motor starter unless instructed to do so
by a Hypertherm Technical Service Associate.
The ambient temperature is too high.
Consider supplemental cooling.
The fan is not generating enough airflow.
• Make sure that the fan motor breaker is not tripped.
• The air cooler fins are dirty or clogged.
• The thermal overload device on the fan motor starter
inside the electrical enclosure turned off the fan motor.
• Turn the OL-FAN dial to RESET and then to AUTO.
The cord for the hydraulic fluid temperature/level
sensor is unplugged or damaged.
• Plug in the sensor.
• Replace the cord.
The temperature sensor is faulty or damaged.
Replace the sensor.
Summary of Contents for HyPrecision 50S
Page 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Page 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Page 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Page 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...