5
Electrical System
5.1
Electrical System Overview
The electrical enclosure contains the main disconnect, the motor starters, and the control components.
All internal control power is derived from the three phase input power. The
Electrical
section of this
manual describes the following:
•
Electrical Control Panel
•
Motors and Motor Starter Circuits
•
Fault Detection
5.2
Electrical Control Panel
Operator Control Station
The operator controls the intensifier pump through the Operator Control Station (OCS) on the front of
the electrical enclosure see
Front Control Panel
in the
Operation
section. Refer to the supplemental
control manual for additional details about control operation and features.
Disconnects and Fuses
The electrical cabinet is powered by 3-phase AC incoming power. All motors are run using the same 3-
phase power input. Some control enclosures may have a transformer for 110VAC as required.
All field components (i.e. solenoid valves, sensors, etc.) use
24VDC
power. Fusing is provided for the
PLC outputs, 24VDC power supply, and the transformer (if present). Refer to the electrical schematic
for fuse sizes and locations. Some spare fuses are included with the controller. All fuses can be
purchased from Hypertherm or an electrical supply store.
Remote Operation Wiring
Hypertherm HyPrecision 100D/150D pumps come standard with built in functionality for
REMOTE
operation. The pump includes two options for external control that integrators can use: External
Pressure Control and Remote Pump Control.
Remote Pump Control (RPC) deactivates the
CONTROLS ON
,
PUMP ON
, and
COOLING ON
at
the front panel of the pump. These inputs are then solely controlled from a remote source.
PUMP OFF
and
EMERGENCY STOP
are active at both the front control panel and the remote source. RPC is
activated by turning the key switch to the remote setting. The wire connections and terminal block
information are included in the schematic for this pump.
23
Summary of Contents for HyPrecision 100D
Page 1: ...Instruction Manual 808310 Revision 0 English Original instructions ...
Page 2: ...Instruction Manual 808310 Revision 0 English March 2014 Hypertherm Inc Hanover NH 03755 USA ...
Page 16: ...14 ...
Page 24: ...22 ...
Page 27: ...25 ...
Page 34: ...32 ...
Page 58: ...56 ...
Page 74: ...72 ...
Page 75: ...12 Drawings and Parts Lists 73 ...
Page 76: ...74 ...
Page 77: ...13 Controls Manual 75 ...