TDS METER
Part #
13897
9.2
Pump Capabilities
50hp
(37kW)
60hp
(45kW)
75hp
(56kW)
100hp
(75kW)
150hp
(112kW)
Frequency (Hz)
50
60
50
60
50
60
50
60
50
60
Max. Continuous
Output Pressure
60,000 psi (4137 bar)
Min. Output
Pressure
8,000 psi (552 bar)
Max. Output Flow
gpm (lpm)
1.0
(3.79)
1.1
(4.16)
1.2
(4.54)
1.3
(4.92)
1.5
(5.68)
1.6
(6.05)
2.1
(7.95)
2.2
(8.33)
3.0
(11.4)
3.2
(12.1)
9.3
Orifice Combinations
This pump will support at least the following orifice sizes (sizes are in inches):
50hp
(37kW)
60hp
(45kW)
75hp
(56kW)
100hp
(75kW)
150hp
(112kW)
Frequency (Hz)
50
60
50
60
50
60
50
60
50
60
1 Orifice
.014
.015
.015
.016
.017
.018
.020
.021
.024
.025
2 Orifices
.010
.010
.011
.011
.012
.013
.014
.015
.017
.018
3 Orifices
.008
.008
.009
.009
.010
.010
.011
.012
.014
.014
4 Orifices
.007
.007
.008
.008
.009
.009
.010
.010
.012
.013
5 Orifices
.006
.006
.007
.007
.008
.008
.009
.009
.011
.011
6 Orifices
N/A
N/A
.006
.006
.007
.007
.008
.008
.010
.010
9.4
Inlet Cutting Water Requirements
Inlet Cutting Water Requirements and Testing
The inlet water should have a pH of 6 to 8 and be clear, odorless, and free of biological
materials. To insure the incoming water will not have an adverse effect on the
diamond life, the water quality can be tested with the TDS meter.
In other cases, it should be analyzed for the following:
•
pH
•
Silica Content
•
Total Dissolved Solids (TDS)
60
Summary of Contents for HyPrecision 100D
Page 1: ...Instruction Manual 808310 Revision 0 English Original instructions ...
Page 2: ...Instruction Manual 808310 Revision 0 English March 2014 Hypertherm Inc Hanover NH 03755 USA ...
Page 16: ...14 ...
Page 24: ...22 ...
Page 27: ...25 ...
Page 34: ...32 ...
Page 58: ...56 ...
Page 74: ...72 ...
Page 75: ...12 Drawings and Parts Lists 73 ...
Page 76: ...74 ...
Page 77: ...13 Controls Manual 75 ...