Motor Fault
Fuse in the control has blown. A
short in a device on the PLC output
may have failed causing the fuse to
blow. A less likely scenario would
be a short in the motor wiring for the
boost motor or main motor.
Check the devices on the PLC outputs to determine what caused
the fuse to blow. If it is a failed solenoid, usually you will see
the plastic body deformed from heat. Check all cables for
damage. Replace any faulty parts.
The main motor thermal overload
(OL-MAIN) may have tripped.
Reset by pushing the reset button on the thermal overload. Refer
to
Electric Motors
in the
Electrical System
section of this
manual.
Too Many Motor Starts Per Hour
The motor has been started too many
times in 15 minutes.
Reset the alarm by pressing the FAULT RESET button on the
control panel. Wait 15 minutes to let the motor armature cool
down before starting again.
Hydraulic pump does not make pressure or makes low pressure.
Defective cut pressure select
solenoid.
Manually over-ride valve until replacement arrives.
Defective cut pressure control valve.
Replace valve.
Defective hydraulic pump and/or
compensator.
Replace pump.
Defective relief valve.
Replace valve.
Pierce pressure is enabled.
Change pierce pressure to cut pressure at the display.
Pump will not start.
Power disconnected.
Reconnect power.
Check main disconnect.
E-Stop depressed.
Pull out all E-stop buttons.
Pump enclosure door open.
Close door and properly latch disconnect handle.
Motor overload relay tripped.
Check and correct.
Adjust volume stop on pump.
Line fuses blown or missing.
Check and correct.
Pump remote key switch in wrong
position.
Change key switch position.
66
Summary of Contents for HyPrecision 100D
Page 1: ...Instruction Manual 808310 Revision 0 English Original instructions ...
Page 2: ...Instruction Manual 808310 Revision 0 English March 2014 Hypertherm Inc Hanover NH 03755 USA ...
Page 16: ...14 ...
Page 24: ...22 ...
Page 27: ...25 ...
Page 34: ...32 ...
Page 58: ...56 ...
Page 74: ...72 ...
Page 75: ...12 Drawings and Parts Lists 73 ...
Page 76: ...74 ...
Page 77: ...13 Controls Manual 75 ...