9
Specifications
The following specifications describe the requirements and capabilities of the AS-Series pumps.
9.1
Pump Requirements
50hp
(37kW)
60hp
(45kW)
75hp
(56kW)
100hp
(75kW)
150hp
(112kW)
Frequency (Hz)
50
60
50
60
50
60
50
60
50
60
Pump Power
Voltage (V)
400
230/4
60
230/46
0
400
460
400
460
400
460
Current (I)
70
135/67
105
95
150
120
215
170
Main C.B. Rating (I)
90
175/10
0
125
125
175
15
0
250
200
Physical
Si
z
e
Width
80in (2.03m)
45 (1.15m)
Length
42in (1.07m)
86 (2.18m)
Height
58in (1.47m)
56 (1.42m)
Clearance Height
80in (2.03m)
80in (2.03m)
80in (2.03m)
Shipping Weight
Approx.
(in crate, no oil)
3200lb
(1450kg)
3300lb (1497kg)
3400lb (1540kg)
4250lb (1928kg)
6250lb (2834kg)
Operating Weight
Approx.
3100lb
(1406kg)
3200lb (1450kg)
3300lb (1497kg)
3300lb (1497kg)
4150lb (1882kg)
6100lb
(2767kg)
Ambient Conditions
Min. Storage Temp.
(not drained)
35°F (1.7°C)
Min. Operating
Temp.
40°F (4.4°C)
Max. Operating
Temp.
95°F (35°C)
Note: higher temperature operation available with additional cooling package
Max. Relative
Humidity
95%
Inlet Cutting Water
Min. Inlet
Water Pressure
40 psi (1.38 bar)
57
Summary of Contents for HyPrecision 100D
Page 1: ...Instruction Manual 808310 Revision 0 English Original instructions ...
Page 2: ...Instruction Manual 808310 Revision 0 English March 2014 Hypertherm Inc Hanover NH 03755 USA ...
Page 16: ...14 ...
Page 24: ...22 ...
Page 27: ...25 ...
Page 34: ...32 ...
Page 58: ...56 ...
Page 74: ...72 ...
Page 75: ...12 Drawings and Parts Lists 73 ...
Page 76: ...74 ...
Page 77: ...13 Controls Manual 75 ...