RPC Operational Connections
Description
Wire No
Voltage
Type Contact
Remote Controls On
1
6027, 5024A
24VDC
Momentary, Normally Open (NO)
Remote E-Stop
5024A, 5024B
24VDC
Normally Closed (NC)
Remote Pump On
6028, 24VDC
24VDC
PLC Input, Momentary, NO
Remote Pump Off
6029, 24VDC
24VDC
PLC Input, Momentary, NC
RPC Status Connections
Description
Wire No
Voltage
Type Contact
Remote Controls On
1
6027, 5024A
24VDC
Momentary, Normally Open (NO)
Remote E-Stop
5024A, 5024B
24VDC
Normally Closed (NC)
Remote Pump On
6028, 24VDC
24VDC
PLC Input, Momentary, NO
Remote Pump Off
6029, 24VDC
24VDC
PLC Input, Momentary, NC
RPC Emergency Stop Connections
Description
Wire No
Voltage
Type Contact
Remote Cooling Mode
6030, 24VDC
24VDC
PLC Input, Momentary or Maintained, NO
Discrete Pressure Input
6022, 6022A
24VDC
PLC Input, Maintained, NO
Controls On Indicator
5024C, 24COM 24VDC
PLC Output
Remote Mode Active Indicator
6027, 24COM
24VDC
PLC Output
Remote Pump Fault Indicator
7004, 24COM
24VDC
PLC Output
Remote Pump Run Indicator
6047, 24COM
24VDC
PLC Output
1
Optionally you can require the operator to turn the key switch to
LOCAL
mode, press the
CONTROLS
ON
button, then
turn the key switch back to
REMOTE
. When doing it this way any time a fault shutdown or E-Stop occurs you will need
to turn the controls on this way at the pump.
24
Summary of Contents for HyPrecision 100D
Page 1: ...Instruction Manual 808310 Revision 0 English Original instructions ...
Page 2: ...Instruction Manual 808310 Revision 0 English March 2014 Hypertherm Inc Hanover NH 03755 USA ...
Page 16: ...14 ...
Page 24: ...22 ...
Page 27: ...25 ...
Page 34: ...32 ...
Page 58: ...56 ...
Page 74: ...72 ...
Page 75: ...12 Drawings and Parts Lists 73 ...
Page 76: ...74 ...
Page 77: ...13 Controls Manual 75 ...