INSTALLATION
HPR130 Manual Gas
Instruction Manual
3-15
6
Install the off-valve
• Mount the off-valve assembly near the torch lifter station. The maximum length of the gas hoses between the
off-valve assembly and the torch is 1.8 m (6 ft).
D
A
A
A-A
30 mm
1.18"
4.7 mm
0.187"
19 mm
.075"
157 mm
6.18"
Off-valve grounding
Vent hole:
Do not block