MAINTENANCE
HPR130 Manual Gas
Instruction Manual
5-5
5
Sequence of operation
1. Power-up – The system verifies that all of these signals are off at power-up
Coolant flow off
Chopper current off
Transfer off
Phase Loss off
Chopper 1 over-temp off
Magnetics over-temp off
Coolant over-temp off
Plasma start off
2. Purge – Air or N
2
gas flows through torch for 20 seconds
Coolant flow on
Contactor closes and the chopper performs a chopper test and a current sensor test
Plasma start off
Contactor opens when the purge cycle ends
3. Idle
Gas pressure ok
Coolant flow on
Chopper current off
Line voltage ok
4. Preflow – 2 second flow of gas
5. Pilot Arc – Current flow between electrode and nozzle
Chopper, main contactor and pilot arc relay are on
High frequency present
Chopper current sensor = pilot arc current
6. Transfer – Pilot arc current sensed on the worklead
7. Ramp-up – Chopper current increases to set point and gas switches to cutflow
Coolant flow on
Gas pressure ok
Phase loss on
Line voltage ok
8. Steady State – normal operating parameters
Coolant flow on
Gas pressure ok
Phase loss on
Chopper 1 over-temp off
Magnetics over-temp off
Coolant over-temp off
9. Ramp-down – Current and gas flow decreases after plasma start has been removed
Cutflow gas off
10. Auto Off – 10 second postflow
Main contactors off
Choppers off
Summary of Contents for HPR130
Page 1: ...Manual gas Instruction manual 804570 Revision 6 HyPerformance Plasma HPR130 ...
Page 40: ...SPECIFICATIONS 2 2 HPR130 Manual Gas Instruction Manual 5 ...
Page 132: ...MAINTENANCE HPR130 Manual Gas Instruction Manual 5 9 PCB block diagram 3 ...
Page 146: ...MAINTENANCE HPR130 Manual Gas Instruction Manual 5 23 CNC operation with pump timeout 5 ...
Page 151: ...MAINTENANCE 5 28 HPR130 Manual Gas Instruction Manual 6 Coolant flow troubleshooting chart ...
Page 195: ...HPR130 Manual Gas Instruction Manual 7 5 Discrete output functionality ...
Page 238: ......
Page 239: ......