SPECIFICATIONS
2-4
HPR130 Manual Gas
Instruction Manual
6
Mild steel
Stainless steel
Aluminum
Gas types
Plasma
Shield
Plasma
Shield
Plasma
Shield
Cutting 30 to 50 A
O
2
O
2
N
2
& F5
N
2
Air
Air
Cutting 80 A
O
2
Air
F5 N
2
Cutting 130 A
O
2
Air
N
2
& H35
N
2
H35 & Air
N
2
& Air
Specifications
System gas requirements
* Oxygen, nitrogen, and air are required for all systems. Nitrogen is used as a purge gas.
** This information can be found in the
Handbook of Compressed Gases
, 3rd edition, Compressed Gas Association,
Van Nostrand Reinhold.
*** ISO standard 8573-1 Class 1.2.2 requirements are:
• Particulates – no more than 100 particles per cubic meter of air at a Size of 0.1 to 0.5 microns in the largest
dimension and 1 particle per cubic meter of air at a Size of 0.5 to 5.0 microns in the largest
dimension.
• Water – there can not be more humidity in the air than in air at –40° C (–40° F).
• Oil – the concentration of oil can be no more than 0.1 mg per cubic meter of air.
Gas quality and pressure requirements
Quality
Grade
**
Pr/- 10%
Flow rate
O
2
Oxygen*
99.5% pure
G
827 kPa / 8.3 bar
4250 l/h 150 scfh
Clean, dry, oil-free
120 psi
N
2
Nitrogen*
99.99% pure
E
827 kPa / 8.3 bar
7080 l/h 250 scfh
Clean, dry, oil-free
120 psi
Air*
*** Clean, dry, oil-free per
K
827 kPa / 8.3 bar
7080 l/h 250 scfh
ISO 8573-1 Class 1.2.2
120 psi
H35
99.995% pure
Ar = A
827 kPa / 8.3 bar
4250 l/h 150 scfh
Argon-hydrogen
(H35 = 65% Argon, 35% Hydrogen)
H
2
= A
120 psi
F5
99.98% pure
N
2
= E
7827 kPa / 8.3 bar
4250 l/h 150 scfh
Nitrogen-hydrogen
(F5 = 95% Nitrogen, 5% Hydrogen)
H
2
= A
120 psi
Summary of Contents for HPR130
Page 1: ...Manual gas Instruction manual 804570 Revision 6 HyPerformance Plasma HPR130 ...
Page 40: ...SPECIFICATIONS 2 2 HPR130 Manual Gas Instruction Manual 5 ...
Page 132: ...MAINTENANCE HPR130 Manual Gas Instruction Manual 5 9 PCB block diagram 3 ...
Page 146: ...MAINTENANCE HPR130 Manual Gas Instruction Manual 5 23 CNC operation with pump timeout 5 ...
Page 151: ...MAINTENANCE 5 28 HPR130 Manual Gas Instruction Manual 6 Coolant flow troubleshooting chart ...
Page 195: ...HPR130 Manual Gas Instruction Manual 7 5 Discrete output functionality ...
Page 238: ......
Page 239: ......