OPERATION
5
4-12
HPR130 Manual Gas
Instruction Manual
Mild steel
O
2
Plasma / Air Shield
80 A Cutting
220189
220173
220187
220176
220179
220188
Flow rates – lpm/scfh
O
2
Air
Preflow
0 / 0
76 / 161
Cutflow
23 / 48
41 / 87
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm
in
mm/min
ipm
Volts
N
2
N
2
10
10
10
10
15
2.5
0.100
6350
250
130
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
mm/m
mm
factor %
seconds
O
2
Air
50
30
72
30
2
112
2.5
9810
3.8
150
0.1
2.5
115
7980
3
117
6145
0.2
4
120
2.0
4300
4.0
200
6
123
3045
0.3
10
127
1810
0.5
15
12
130
1410
5.0
250
0.7
15
133
1030
0.8
20
135
2.5
545
6.3
0.9
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
ipm
in
factor %
seconds
O
2
Air
50
30
72
30
.075
112
0.100
400
0.150
150
0.1
.105
115
290
.135
117
180
0.2
3/16
120
0.080
155
0.160
200
1/4
123
110
0.3
3/8
127
75
0.5
15
1/2
130
50
0.200
250
0.7
5/8
133
37
0.8
3/4
135
0.100
25
0.250
0.9
Summary of Contents for HPR130
Page 1: ...Manual gas Instruction manual 804570 Revision 6 HyPerformance Plasma HPR130 ...
Page 40: ...SPECIFICATIONS 2 2 HPR130 Manual Gas Instruction Manual 5 ...
Page 132: ...MAINTENANCE HPR130 Manual Gas Instruction Manual 5 9 PCB block diagram 3 ...
Page 146: ...MAINTENANCE HPR130 Manual Gas Instruction Manual 5 23 CNC operation with pump timeout 5 ...
Page 151: ...MAINTENANCE 5 28 HPR130 Manual Gas Instruction Manual 6 Coolant flow troubleshooting chart ...
Page 195: ...HPR130 Manual Gas Instruction Manual 7 5 Discrete output functionality ...
Page 238: ......
Page 239: ......