APPENDIX C – BEVEL CUTTING
HPR130 Manual Gas
Instruction Manual
c-11
1. Leads for use with the standard quick-disconnect (220163)
All leads have standard fittings that are identical to the hoses listed in the
Installation
section in this manual. The only
difference is that the gas leads have been extended to 2.5 m (8.17 ft).
2. Leads for use with the bevel quick-disconnect/short torch-sleeve assembly (220573)
All of the gas leads have push-to-connect fittings and can only be used with the 220573 assembly. The 2 hoses to the
off-valve have adapters that change the push-to-connect fitting to a screw-on fitting.
*Use of these lead assemblies will result in reduced consumable life.
Part number
Overall length
Gas lead length
228075
1.83 m (6 ft)
1.83 m (6 ft)
228076
3.05 m (10 ft)
1.83 m (6 ft)
228079
4.5 m (15 ft)
1.83 m (6 ft)
228081
7.5 m (25 ft)
1.83 m (6 ft)
228083
10 m (35 ft)
1.83 m (6 ft)
228086
15 m (50 ft)
1.83 m (6 ft)
228088
20 m (65 ft)
1.83 m (6 ft)
228077*
3.05 m (10 ft)
2.5 m (8.17 ft)
228061*
4.5 m (15 ft)
2.5 m (8.17 ft)
228062*
7.5 m (25 ft)
2.5 m (8.17 ft)
228084*
10 m (35 ft)
2.5 m (8.17 ft)
228063*
15 m (50 ft)
2.5 m (8.17 ft)
228089*
20 m (65 ft)
2.5 m (8.17 ft)
Part number
Overall length
Gas lead length
128986
1.83 m (6 ft)
1.83 m (6 ft)
128935
3.05 m (10 ft)
1.83 m (6 ft)
128934
4.5 m (15 ft)
1.83 m (6 ft)
128784
7.5 m (25 ft)
1.83 m (6 ft)
128987
10 m (35 ft)
1.83 m (6 ft)
128785
15 m (50 ft)
1.83 m (6 ft)
128988
20 m (65 ft)
1.83 m (6 ft)
228040*
4.5 m (15 ft)
2.5 m (8.17 ft)
228043*
7.5 m (25 ft)
2.5 m (8.17 ft)
228065*
10 m (35 ft)
2.5 m (8.17 ft)
228045*
15 m (50 ft)
2.5 m (8.17 ft)
228066*
20 m (65 ft)
2.5 m (8.17 ft)
Summary of Contents for HPR130
Page 1: ...Manual gas Instruction manual 804570 Revision 6 HyPerformance Plasma HPR130 ...
Page 40: ...SPECIFICATIONS 2 2 HPR130 Manual Gas Instruction Manual 5 ...
Page 132: ...MAINTENANCE HPR130 Manual Gas Instruction Manual 5 9 PCB block diagram 3 ...
Page 146: ...MAINTENANCE HPR130 Manual Gas Instruction Manual 5 23 CNC operation with pump timeout 5 ...
Page 151: ...MAINTENANCE 5 28 HPR130 Manual Gas Instruction Manual 6 Coolant flow troubleshooting chart ...
Page 195: ...HPR130 Manual Gas Instruction Manual 7 5 Discrete output functionality ...
Page 238: ......
Page 239: ......