SPECIFICATIONS
HPR130 Manual Gas
Instruction Manual
2-5
6
Power supply
General
Maximum OCV (U
0
)
311 VDC
Maximum output current (I
2
)
130 Amps
Output voltage (U
2
)
50 – 150 VDC
Duty cycle rating (X)
100% @ 19.5 kw, 40° C (104° F)
Ambient temperature/Duty cycle
Power supplies will operate between -10° C and +40° C (+14° and 104° F)
Power factor(cos
ϕ
)
0.88 @ 130 ADC output
Cooling
Forced air (Class F)
Insulation
Class H
Part
number
AC Voltage
(U
1
)
Phase
Frequency
(Hz)
Amperage (I
1
)
Regulatory
approval
Power kW
(+/- 10%)
(U
1
x I
1
x 1.73)
078177
200/208
3
50/60
62/60
CSA
21.5
078178
220
3
50/60
57
CSA
21.5
078179
240
3
60
52
CSA
21.5
078193
380
3
50/60
33
CCC
21.5
078180
400
3
50/60
32
CE/GOST-R
21.5
078182
440
3
50/60
28
CSA
21.5
078181
480
3
60
26
CSA
21.5
078183
600
3
60
21
CSA
21.5
317.5 kg
700 lb
154.9 mm
6.1"
1079.5 mm
42.5"
967.7 mm
38.1"
566.4 mm
22.3"
Summary of Contents for HPR130
Page 1: ...Manual gas Instruction manual 804570 Revision 6 HyPerformance Plasma HPR130 ...
Page 40: ...SPECIFICATIONS 2 2 HPR130 Manual Gas Instruction Manual 5 ...
Page 132: ...MAINTENANCE HPR130 Manual Gas Instruction Manual 5 9 PCB block diagram 3 ...
Page 146: ...MAINTENANCE HPR130 Manual Gas Instruction Manual 5 23 CNC operation with pump timeout 5 ...
Page 151: ...MAINTENANCE 5 28 HPR130 Manual Gas Instruction Manual 6 Coolant flow troubleshooting chart ...
Page 195: ...HPR130 Manual Gas Instruction Manual 7 5 Discrete output functionality ...
Page 238: ......
Page 239: ......