INSTALLATION
3-26
HPR130 Manual Gas
Instruction Manual
3
Examples of output circuits
1. Logic interface, active-high
2. Logic interface, active-low
3. Relay interface
4. Do not use this configuration. Warranty will be void.
High-impedance (
≤
10mA)
10K
(optional)
CNC/PLC
5VDC-24VDC
C
HPR
E
+
–
HPR
C
E
+
–
5VDC-24VDC
High-impedance (
≤
10mA)
CNC/PLC
10K
(optional)
CNC/PLC
CNC +24V
+24VDC
CNC +24V
HPR
C
E
+
–
Power
ground
External relay
24VDC low-power coil
≤
10mA or
≥
2400ohm
High-current
contact closure
inputs (AC or DC)
°t
Any voltage
VO
IDS
WA
RRANTY
HPR
Install a
Jumper
108056
J304
C
E
+
–