HMI Parameter Value
<back>
Return to Main display
Errors
The latest and currently active error condition. Normal errors are cleared on the next start. Critical
errors must be corrected before the next start.
Normal errors
NO ERRORS
Ready to start.
ERR 1 FLASH SETUPS
Checksum failed on stored setups in flash memory, the
THC is using default values.
ERR 2 MAX SPEED EXCEEDED
A speed regulation problem occurred — the value for
Maximum Speed was exceeded.
ERR 3 LIFTER HOME TIMEOUT
Lifter did not return to home position within 20 seconds.
ERR 4 PLATE CONTACT AT HOME
Ohmic contact with the workpiece at home position —
an invalid condition.
ERR 5 HOME LIM DURING OPR
The Lifter reached the Home limit during auto operation.
ERR 6 LOWER LIM DURING OPR
The lifter reached the Lower limit during auto operation.
Diagnostics screen
The Diagnostics display on the HMI provides information about errors that the HMI receives from the control module, the
control state of the cutting system, as well as whether Hypernet is enabled and diagnostics for the switches on the front
panel of the HMI. The following table provides details for the parameters that can appear on the Diagnostics display.
For detailed information about resolving errors, see the
Maintenance
section.
Diagnostics
<back>
NO ERRORS
Control State
0
Summary of Contents for ArcGlide Torch Height Control
Page 1: ...Instruction Manual 806450 Revision 3 November 2010 ArcGlide THC...
Page 2: ......
Page 16: ...English Hypertherm Safety and Compliance S 8...
Page 34: ...1 14 ArcGlide THC Instruction Manual Specifications...
Page 48: ...2 12 ArcGlide THC Instruction Manual INSTALLATION...
Page 100: ...2 64 ArcGlide THC Instruction Manual INSTALLATION...
Page 202: ...6 4 ArcGlide THC Instruction Manual Wiring Diagrams...
Page 207: ......
Page 208: ......