ArcGlide THC
Instruction Manual
4-27
MAINteNANCe
error Description
Possible Causes
Corrective action
12
The ArcGlide did not
receive the Transfer signal
from the plasma system
before the transfer time
expired.
In a Hypernet system,
check the Transfer Time
setting in the Plasma
Process screen.
Fault Transfer (or motion)
output from the plasma
system.
The torch did not produce
an arc.
In a discrete system,
there was a faulty input
(Transfer) to the control
module.
Check the transfer time setting in the CNC (Hypernet
only). The transfer time needs to be long enough to
allow the plasma system to purge gases. In an HPR,
this could be up to 10 seconds.
Check the plasma system for an error.
Make sure the plasma system is firing over metal.
Check the plasma interface cable for damage.
Check the Plasma Start input to the plasma system. If
plasma system torch fires:
•
Verify the Plasma Start wiring at the plasma
interface PCB.
•
Check that the torch consumables and cutting
process are correct.
•
Check the Plasma interface cable for damage.
In a discrete system:
Check the Plasma Start input to the control module.
Check the Transfer (or motion) output from the
plasma system.
Check the Transfer input to the control module.
2
Summary of Contents for ArcGlide Torch Height Control
Page 1: ...Instruction Manual 806450 Revision 3 November 2010 ArcGlide THC...
Page 2: ......
Page 16: ...English Hypertherm Safety and Compliance S 8...
Page 34: ...1 14 ArcGlide THC Instruction Manual Specifications...
Page 48: ...2 12 ArcGlide THC Instruction Manual INSTALLATION...
Page 100: ...2 64 ArcGlide THC Instruction Manual INSTALLATION...
Page 202: ...6 4 ArcGlide THC Instruction Manual Wiring Diagrams...
Page 207: ......
Page 208: ......