2-44
ArcGlide THC
Instruction Manual
INStALLAtIoN
2
Part number
Length
Part number
Length
223227
3.0 m (10 ft)
223103
23.0 m (75 ft)
223228
6.0 m (20 ft)
223104
30.5 m (100 ft)
223123
7.5 m (25 ft)
223105
45.5 m (150 ft)
223229
10.5 m (35 ft)
223106
61.0 m (200 ft)
223004
15.0 m (50 ft)
Plasma interface I/o cable
Blue band
Connect this end to
the port on the control
module with the blue
circle.
Connect this end to the
discrete plasma interface
at the plasma system
Pins 38 – 50 are not used.
Note: For more information about discrete plasma I/O signals, see
ArcGlide discrete interface signals
.
* Pin numbers are the same on both ends of the cable.
Pin number* Color
Signal name
Dry contact
circuit
Sourced
circuit
1
Red
RS422 Rx +
2
Black
RS422 Rx -
3
White
RS422 Tx +
4
Black
RS422 Tx –
5
Green
RS422 common
6
Black
Motion input +
7
Blue
Motion input –
8
Black
Error input +
9
Yellow
Error input –
10
Black
Rampdown error input +
11
Brown
Rampdown error input –
12
Black
Not ready input +
13
Orange
Not ready input –
14
Black
Spare input +
15
White
Spare input –
+
_
3.9 K
+
_
3.9 K +24 V
3.9 K
+
_
3.9 K +24 V
3.9 K
+
_
3.9 K +24 V
3.9 K
+
_
3.9 K +24 V
3.9 K
+
_
3.9 K +24 V
3.9 K
+
_
3.9 K
+
_
3.9 K
+
_
3.9 K
+
_
3.9 K
Summary of Contents for ArcGlide Torch Height Control
Page 1: ...Instruction Manual 806450 Revision 3 November 2010 ArcGlide THC...
Page 2: ......
Page 16: ...English Hypertherm Safety and Compliance S 8...
Page 34: ...1 14 ArcGlide THC Instruction Manual Specifications...
Page 48: ...2 12 ArcGlide THC Instruction Manual INSTALLATION...
Page 100: ...2 64 ArcGlide THC Instruction Manual INSTALLATION...
Page 202: ...6 4 ArcGlide THC Instruction Manual Wiring Diagrams...
Page 207: ......
Page 208: ......