ArcGlide THC
Instruction Manual
3-11
oPeRAtIoN
2
Main parameters
The Main screen is the primary display that the operator sees during normal operation.
HMI Parameter Value
Operation mode
and the current
THC state
Use the Auto/Manual switch to select automatic or manual operation:
•
Auto = Automatic torch height sequencing ( IHS, Cut Height, AVC, Retract). See
Diagnostics
for more information on control states.
•
Manual = Torch height changes with manual commands only.
Use the Enable/Disable switch to enable or disable the torch:
•
Disabled = The torch retracts to Home position and Parks. If it is capable, the plasma system
powers down.
Errors
The latest, and currently active error condition, sent from the control module.
Set Volts
50 V to 300 V with 0.1-volt resolution. This line displays only if Sampled Arc Voltage is not
enabled.
Cut Height
Inch or equivalent mm – 0.254 mm to 25.40 mm (0.01 in to 1.0 in) with 0.254 mm (0.01 in)
resolution
Pierce Height
Inch or equivalent mm – 0.254 mm to 25.40 mm (0.01 in to 1.0 in) with 0.254 mm (0.01 in)
resolution
Pierce Delay
0 to 10 seconds with 0.01 second resolution
AVC Enabled
When AVC is enabled (ON), Automatic Height Control is active in Auto mode. When AVC is
disabled (OFF), the torch height sequences in Auto mode (IHS, Cut Height, Retract) but the torch
height remains fixed during the cut.
<Setup
Parameters>
Select this line to display the Setup Parameters menu.
Auto
IDLE PARK
NO ERRORS
Set Volts
133.5v
Cut Height
0.13in
Summary of Contents for ArcGlide Torch Height Control
Page 1: ...Instruction Manual 806450 Revision 3 November 2010 ArcGlide THC...
Page 2: ......
Page 16: ...English Hypertherm Safety and Compliance S 8...
Page 34: ...1 14 ArcGlide THC Instruction Manual Specifications...
Page 48: ...2 12 ArcGlide THC Instruction Manual INSTALLATION...
Page 100: ...2 64 ArcGlide THC Instruction Manual INSTALLATION...
Page 202: ...6 4 ArcGlide THC Instruction Manual Wiring Diagrams...
Page 207: ......
Page 208: ......