ArcGlide THC
Instruction Manual
2-49
INStALLAtIoN
2
Dry contact inputs
Voltage sourced inputs
3.9 K
3.9 K
3.9 K
12 VDC to 24 VDC
12 VDC to 24 VDC
12 VDC to 24 VDC
(external supply)
Switch
ArcGlide internal circuitry
+
–
+
–
+
–
ArcGlide discrete interface signal examples
Inputs
The figures below show simplified schematics of the ArcGlide THC inputs. The inputs for both CNC and plasma can be
configured for dry contacts (no external voltage), the default, or for positive voltage sourced inputs. The inputs have two
different modes that are selected using switches behind the calibration and setup door on
the top right front of the control module.
The mode that is selected automatically compensates for the polarity reversal so that in both
cases a closed switch input will activate the signal.
All inputs to the lifter interface and operator console interface are fixed in the dry contact
mode.
Switch
optoisolator
Relay
+24 V
+24 V
+24 V
3.9 K
3.9 K
3.9 K
3.9 K
3.9 K
3.9 K
ArcGlide internal circuitry
+
–
+
–
+
–