h120bASIc uSEr mAnuAL EdItIon II 2016-12-28
5. start up
5.1 Position
Place the machine on a stable and level surface.
5.2 Filling the oil
H120BASIC is supplied without oil in the tank. The tank holds 180 liters. Open backside cover on the
machine. Open the fi lling cap (1) and fi ll up as much oil as possible. Fill to the mark on the sight
glass. (2)
Below recommended oil shoud be used:
Recommended oil:
ISO VG46 or equivalent.
5.3 electrical installation
The machine is supplied without cable and plug. Contact a licensed electrician for electrical
installations. Check that the main voltage corresponds to the rated voltage of the machine before it
is connected to the network.
note!
Check direction of rotation of the pump. If reversed (wrong) rotation, the pump will be quiet
and you will hear a little bubbling sound in the tank. You can not run the machine! Is the pump in
the right direction, it will have a relatively high noise level of up to a minute then it will be almost
completely silent. It is now possible to run the machine!
5.4 selecting die set
determine the crimping dimensions for the current operation and select the die set with the correct
interval that corresponds to the crimping measurement.
For example: A crimping measurement of 17 mm requires the die set size nr 16 (since it covers the
16-19 mm interval).
Always select the die set within the correct interval to achieve the best crimping
results. Every die is marked with the smallest crimping measurement in the interval. crimping any
measurements outside the table crimping measurement interval is not recommended. Using dies that
are too small risk the ferrule becoming oval.
5.5 setting crimping measurements
Turn the adjustment dial so that the zero (0) on the dial is lined-up with the zero (0) in the window.
If zero (0) is set, the machine will crimp the smallest diameter provided in the interval. Every revolu-
tion of the dial increases the value in the window with one unit. one revolution clock-wise corresponds
to 1 mm on the crimping measurement. The measurement shall be added to the least-specifi ed diame-
ter in the interval. For example: Crimping 16 mm hose requires die nr 16 with the adjustment dial set
to zero (0) and lined up with zero (0) in the window. crimping 21,2 mm hose requires die nr 19 with
the adjustment dial turned (two clock-wise rotations) at 2. Selecting 20 on the dial should line up with
2 in the window. make sure to lock the dial when the desired crimping measurement is set.
1
2
Summary of Contents for H120BASIC
Page 1: ...UseR MAnUAL edition II 2016 12 28 serial number H120BAsIC...
Page 15: ...Page 15 H120BASIC USER MANUAL EDITION II 2016 12 28 9 Electrical Draws...
Page 16: ...Page 16 H120BASIC USER MANUAL EDITION II 2016 12 28 9 Electrical Draws...
Page 17: ...Page 17 H120BASIC USER MANUAL EDITION II 2016 12 28 9 Electrical Draws...
Page 18: ...Page 18 H120BASIC USER MANUAL EDITION II 2016 12 28 9 Electrical Draws...
Page 19: ...Page 19 H120BASIC USER MANUAL EDITION II 2016 12 28 9 Electrical Draws...
Page 20: ...Page 20 H120BASIC USER MANUAL EDITION II 2016 12 28 9 Electrical Draws...
Page 21: ...Page 21 H120BASIC USER MANUAL EDITION II 2016 12 28 9 Electrical Draws...
Page 22: ...Page 22 H120BASIC USER MANUAL EDITION II 2016 12 28 9 Electrical Draws...
Page 23: ...Page 23 H120BASIC USER MANUAL EDITION II 2016 12 28 9 Electrical Draws...
Page 24: ...Page 24 H120BASIC USER MANUAL EDITION II 2016 12 28 9 Electrical Draws...