34
Page
DISPLAY OF THE CONTROLLER
The
below shows an example of the display of the controllers.
The exact display may
from examples.
•
Flow rate to
acti
vate the micro-boiler: 0.5 gallon per minute at the default set
temperature (1.9 L/min).
•
Flow rate to keep the micro-boiler running: 0.4 gallon per minute (1 .5 L/min)
•
The controllers have an energy saving mode. Five minutes
after
the micro-boiler
stops
operating
, the backlight of the controller turns o
ff
.
•
The backlight of the controller will turn back on once the micro-boiler begins
firing
again.
GENERAL
"COLD"
Button
"HOT" Bu
tton
Press the "HOT" bu
tt
on or the "COLD"
bu
tt
on to set the hot water temperature.
"ON/OFF"
Button
Press this bu
tt
on to start
or stop opera
tion
.
STAND BY LED
(Orange)
The indicator turns on when the
boiler is ready for opera
tion.
IN USE LED
(Green)
This lights during combus
tio
n.
When the STAND BY LED is ON, the
hot water set temperature will be
displayed.
Display
for
Temperature
NORMAL OPERATION
°F
100 105 110 115 120* 125 130 135 140
°C
38
40
43
45 50* 52
55
57
60
*Factory se
tting
(Default)
TEMPERATURE TABLE OF THE CONTROLLER
"INFO" Bu
tton
Each
the
is pressed,
the
mode is selected
in the following sequence.
Inlet water
temperature
Outlet water
temperature
Water
Owner's Guide