12
Page
-DIPswitch se
ttings
for Ve
n
t
length-
Vent length
Two-pipe and Single pipe
5 to 50
ft.
(DEFAULT)
No. 6 : ON
No. 7 : OFF
51 to 100
ft.
No. 6 : OFF
No. 7 : OFF
OFF
ON 1 2 3 4 5 6 7 8 9 10
OFF
ON 1 2 3 4 5 6 7 8 9 10
Vent length
Two-pipe
5 to 20
ft.
(DEFAULT)
No. 6 : ON
No. 7 : OFF
21 to 40
ft.
No. 6 : OFF
No. 7 : OFF
41 to 70
ft.
No. 6 : ON
No. 7 : ON
OFF
ON 1 2 3 4 5 6 7 8 9 10
OFF
ON 1 2 3 4 5 6 7 8 9 10
OFF
ON 1 2 3 4 5 6 7 8 9 10
Set DIPswitches shown in the tables below depending on the vent length. Only adjust switches with a black
square. Black squares indicate the
position
of the switch.
Vent length
Single pipe
5 to 45
ft.
(DEFAULT)
No. 6 : ON
No. 7 : OFF
46 to 70
ft.
No. 6 : OFF
No. 7 : OFF
OFF
ON 1 2 3 4 5 6 7 8 9 10
OFF
ON 1 2 3 4 5 6 7 8 9 10
Vent length
Single pipe
5 to
6.5
ft.
No. 6 : ON
No. 7 : ON
OFF
ON 1 2 3 4 5 6 7 8 9 10
2 inch ven
ting
3 inch ven
ting
4 inch ven
ting
Summary of Contents for HS120CON-LP