35
Page
Opera
tion
Scr
een
on
the c
on
tr
oller
1.
Turn on the 120 VAC power supply to the
micro-boiler.
2.
Press the
"ON/OFF"
bu
tt
on on the controller in
order to turn the controller on.
3.
When ON, the STAND BY LED is lit.
4.
It shows
the set temperature on its display as shown
in the picture on the right. (EX.: 120 °F)
5.
Press the
"HOT"
bu
tt
on or the
"COLD"
bu
tt
on to set
the temperature se
tting
of the unit.
(EX.: 120 °F)
TEMPERATURE SETTINGS
There are 2 preset temperatures (120 °F (49 °C) and 140 °F (60 °C)) that you can select from by changing
the DIPswitch se
ttings
on the computer board. See the table below. When the controller is in normal
opera
tion,
the set temperature of the controller is given priority over the set temperature of the
DIPswitch se
ttings.
•
The temperature has been preset at the factory to 120 °F (49 °C).
Compu
ter
boa
rd
Bank of
DIPswitches
NOTE:
Only change the switches with dark squares.
The dark squares
indicate the dir
ection
the DIPswitches should be set to.
120 °F (49 °C)
DEFAULT
140 °F (60 °C)
No. 9 : OFF
No. 9 : ON
OFF
ON 1 2 3 4 5 6 7 8 9 10
OFF
ON 1 2 3 4 5 6 7 8 9 10