-Exhaust vent (ABS, PVC, CPVC, or polypropylene vent)-
The micro-boiler can be vented with ABS, PVC, CPVC, or polypropylene (temperature rated up to at
least 149 °F). Vent mat
erial certified
to ULC S636 standards is recommended in the USA. In Canada,
plas
tic
ven
ting mu
s
t be certified
to ULC S636 standards.
•
The maximum length of exhaust vent piping must not exceed 70
ft
. (21.3 m) for 3” ven
tin
g, which
depends on the eleva
tion
where the micro-boiler is installed, and
100 ft.
(30.5 m) for 4” ven
ting
(deducting
5
ft
. (1.5 m) for each elbow used in the ven
ting
system). Do not use more than 5
elbows. See the table below.
•
When the horizontal vent run exceeds 5
ft
. (1.5 m), support the vent run at 3
ft
. (0.9 m) intervals
with overhead hangers.
Item
Material
United States
Canada
Exhaust pipe and
Fi
ttings
Schedule 40 PVC
ANSI/ASTM D1785
ULC S636
Certified
Materials Only
PVC-DWV
ANSI/ASTM D2665
Schedule 40 CPVC
ANSI/ASTM F441
Schedule 40 ABS-DWV
ANSI/ASTM D2661
Polypropylene
UL-1738
Pipe Cement/Primer
PVC
ANSI/ASTM D2564
CPVC
ANSI/ASTM F493
ABS
ANSI/ASTM D2235
NOTE: Do NOT Use Cellular Foam Core Pipe
*For each elbow added, deduct 5
ft.
(1.5
m) from ma
x.
vent leng
th.
For details on the vent c
onnection,
refer to p. 13 to 16.
No.
of
Elbow
2" ven
ting
3" ven
ting
4" ven
ting
Up to 3,000
ft
Up to 3,000
ft
Up to 6,000
ft
Up to 10,100
ft
Up to 10,100
ft
0
6.5
ft
. (2.0 m)
70
ft
. (21.3 m) 40
ft
. (12.2 m)
25
ft
. (7.6 m) 100
ft
. (30.5 m)
1
1.5
ft
. (0.5 m)
65
ft
. (19.8 m) 35
ft
. (10.7 m)
20
ft
. (6.1 m)
95
ft
. (29.0 m)
2
N/A
60
ft
. (18.3 m)
30
ft
. (9.1 m)
15
ft
. (4.6 m)
90
ft
. (27.4 m)
3
N/A
55
ft
. (16.8 m)
25
ft
. (7.6 m)
10
ft
. (3.0 m)
85
ft
. (25.9 m)
4
N/A
50
ft
. (15.2 m)
20
ft
. (6.1 m)
5
ft
. (1.5 m)
80
ft
. (24.4 m)
5
N/A
45
ft
. (13.7 m)
N/A
N/A
75
ft
. (22.9 m)
Excludes vent terminators, termina
tion
elbows, or rain caps.
Ma
x.
V
erti
cal or Horizontal (Total) Vent Lengh