59
EE
12
VDC
voltage
too
low
protection
1.
Data
mistake
2.
Wrong
compressor
phase
connection
3.
Compressor
liquid
and
oil
accumulation
lead
to
the
current
becomes
larger
4.Poor
heat
dissipation
of
drive
module
or
high
ambient
temperature
5.
Compressor
or
driver
board
damaged
1.
Program
error,
turn
off
electricity
supply
and
restart
after
3
minutes
2.
Check
compressor
sequence
connection
3.
Check
the
pressure
of
system
by
pressure
gauge
4.
Check
if
the
ambient
and
water
temperature
is
over
high
5.
If
it
is
the
refrigerant
system
failure,
send
it
to
the
service
center
6.
Change
driver
board
EE
13
Input
current
over
high
protection.
1.
Mother
line
voltage
is
too
low
2.
Driver
board
is
damaged.
1.
Check
if
the
power
supply
is
in
the
normal
range
2.
Change
driver
board
EE
14
IPM
module
thermal
circuit
is
abnormal
1.
The
compressor
current
is
too
large
momentary
2.
The
water
flow
is
abnormal
3.
Power
fluctuations
within
a
short
time
4.
Wrong
reactor
1.
Check
the
compressor
if
it
works
normally
2.
Check
the
waterway
system
3.
Check
if
the
power
is
in
the
normal
range
4.
Check
if
the
reactor
is
used
correctly.
EE
15
IPM
module
temperature
too
high
protection
1.
Output
abnormity
of
IPM
module
thermal
circuit
2.
Fan
motor
is
abnormal
or
damaged
3.
Fan
blade
is
broken
1.
Check
if
the
motor
speed
is
too
low
or
fan
motor
is
damaged,
replace
it
by
a
new
one.
2.
Replace
a
new
driver
board
3.
Change
the
fan
blade
if
it
is
broken
EE
16
PFC
module
protection
1.
Output
exception
of
IPM
module
thermal
circuit
2.
Fan
motor
is
abnormal
or
damaged
3.
Fan
blade
is
broken
4.The
screw
on
driver
board
is
loose
1.
Check
the
main
board
or
replace
the
driver
board
2.
Check
if
the
motor
speed
is
too
low
or
fan
motor
is
damaged,
replace
it
by
a
new
one
if
any
failure.
3.
Change
the
fan
blade
if
it
is
broken
4.
Check
the
screw
on
driver
board
EE
17
DC
fan
motor
failure
1.
DC
motor
is
damaged
2.
For
the
tri
‐
phase
check
if
the
neutral
is
connected
3.
Main
board
is
damaged
4.
The
fan
blade
is
stuck
1.
Detect
DC
motor
for
mono
phase
machine,
replace
a
new
one
if
any
failure
2.
Check
the
wiring
connection
for
tri
‐
phase
machine
3.
Check
the
board,
replace
a
new
driver
board
or
main
board
if
any
failure
4.
Check
if
there
is
any
barrier
in
front
of
fan
blade
and
remove
it
EE
18
PFC
module
thermal
circuit
is
abnormal
The
driver
board
is
damaged
1.
Check
if
the
motor
speed
is
too
low
or
fan
motor
is
damaged,
replace
it
by
a
new
one.
2.
Change
a
new
driver
board
EE
19
PFC
module
high
1.
PFC
module
thermal
circuit
output
1.
Check
the
main
board
or
replace
the
Summary of Contents for 5
Page 8: ...7 2 Wymiary mm Model Inverter 5 Inverter 7 Inverter 10 Model Inverter 13 Inverter 18 ...
Page 31: ...30 ...
Page 35: ...34 Naciśnij i przytrzymaj przez 5 sekund aż zacznie migać ...
Page 45: ...44 2 Dimension mm Model Inverter 5 Inverter 7 Inverter 10 Model Inverter 13 Inverter 18 ...
Page 70: ...69 3 Opertion of Alsova Pro APP Press and hold 5 second until is flashing ...
Page 80: ...79 Model Inverter 13 Inverter 18 ...
Page 107: ...10 3 Die Hauptschnittstelle Wechselrichter 5 Sekunden gedrückt halten bis blinkt ...
Page 111: ...110 überprüfen ...
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ...A0111HYIELR3204 ...