45
3.
Installation
and
connection
3.1
Notes
The
factory
supplies
only
the
heat
pump.
All
other
components,
including
a
bypass
if
necessary,
must
be
provided
by
the
user
or
the
installer.
Attention:
Please
observe
the
following
rules
when
installing
the
heat
pump:
1.
Any
addition
of
chemicals
must
take
place
in
the
piping
located
downstream
from
the
heat
pump.
2.
Install
a
bypass
if
the
water
flow
from
the
swimming
pool
pump
is
more
than
20%
greater
than
the
allowable
flow
through
the
heat
exchanger
of
the
heat
pump.
3.
Always
place
the
heat
pump
on
a
solid
foundation
and
use
the
included
rubber
mounts
to
avoid
vibration
and
noise.
4.
Always
hold
the
heat
pump
upright.
If
the
unit
has
been
held
at
an
angle,
wait
at
least
24
hours
before
starting
the
heat
pump.
3.2
Heat
pump
placement
The
unit
will
work
properly
in
any
desired
location
as
long
as
the
following
three
items
are
present:
1.
Fresh
air
–
2.
Electricity
–
3.
Swimming
pool
filters
The
unit
may
be
installed
in
virtually
any
outdoor
location
as
long
as
the
specified
minimum
distances
to
other
objects
are
maintained
(see
drawing
below).
Please
consult
your
installer
for
installation
with
an
indoor
pool.
Installation
in
a
windy
location
does
not
present
any
problem
at
all,
unlike
the
situation
with
a
gas
heater
(including
pilot
flame
problems).
ATTENTION:
Never
install
the
unit
in
a
closed
room
with
a
limited
air
volume
in
which
the
air
expelled
from
the
unit
will
be
reused,
or
close
to
shrubbery
that
could
block
the
air
inlet.
Such
locations
impair
the
continuous
supply
of
fresh
air,
resulting
in
reduced
efficiency
and
possibly
preventing
sufficient
heat
output.
See
the
drawing
below
for
minimum
dimensions.
3.3
Distance
from
your
swimming
pool
The
heat
pump
is
normally
installed
within
a
perimeter
area
extending
7.5
m
from
the
swimming
pool.
The
greater
the
distance
from
the
pool,
the
greater
the
heat
loss
in
the
pipes.
As
the
pipes
are
mostly
underground,
the
heat
loss
is
low
for
distances
up
to
30
m
(15
m
from
and
to
the
pump;
30
m
in
total)
unless
the
ground
is
wet
or
the
Summary of Contents for 5
Page 8: ...7 2 Wymiary mm Model Inverter 5 Inverter 7 Inverter 10 Model Inverter 13 Inverter 18 ...
Page 31: ...30 ...
Page 35: ...34 Naciśnij i przytrzymaj przez 5 sekund aż zacznie migać ...
Page 45: ...44 2 Dimension mm Model Inverter 5 Inverter 7 Inverter 10 Model Inverter 13 Inverter 18 ...
Page 70: ...69 3 Opertion of Alsova Pro APP Press and hold 5 second until is flashing ...
Page 80: ...79 Model Inverter 13 Inverter 18 ...
Page 107: ...10 3 Die Hauptschnittstelle Wechselrichter 5 Sekunden gedrückt halten bis blinkt ...
Page 111: ...110 überprüfen ...
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ...A0111HYIELR3204 ...