43
1.Specifications
Technical
data
hydro
‐
pro
inverter
pool
heat
pumps
Model
Inverter
5
Inverter
7
Inverter
10
Inverter
13
Inverter
18
Item
No.
7027950
7027951
7027952
7027953
7027954
*
Performance
at
Air
28
℃
,
Water
28
℃
,
Humidity
80%
Heating
capacity
kW
5
‐
3.2
7
‐
3.3
9
‐
3.5
11
‐
4.8
16
‐
5.3
Power
consumption
kW
0.98
‐
0.43
1.32
‐
0.43
1.61
‐
0.43
1.96
‐
0.56
2.85
‐
062
C.O.P.
7.4
‐
5.1
7.7
‐
5.3
8.5
‐
5.6
8.5
‐
5.6
8.5
‐
5.6
*
Performance
at
Air
15
℃
,
Water
26
℃
,
Humidity
70%
Heating
capacity
kW
3.7
‐
2.3
4.7
‐
2.4
6.6
‐
2.5
7.9
‐
3.5
11.2
‐
3.8
Power
consumption
kW
0.93
‐
0.43
1.18
‐
0.43
1.65
‐
0.43
1.98
‐
0.6
2.8
‐
0.66
C.O.P.
5.4
‐
4
5.6
‐
4
5.8
‐
4
5.8
‐
4
5.8
‐
4
*
General
data
Compressor
type
Inverter
Compressor
Voltage
V
220~240V
/
50Hz
or
60Hz
/1PH
Rated
current
A
4.40
5.90
7.20
8.70
11.90
Minimum
fuse
A
7.00
9.00
11.00
13.00
18.00
Advised
pool
volume
(with
pool
cover)
m³
0
‐
20
10
‐
25
15
‐
40
20
‐
50
30
‐
85
Advised
water
flux
m
3
/h
2.50
2.50
2.80
3.70
4.60
Water
pressure
drop
Kpa
12
12
12
14
15
Heat
exchanger
Twist
‐
titanium
tube
in
PVC
Water
connection
mm
50
No.
of
Fan
1
Ventilation
type
Horizontal
Fan
speed
RPM
650
‐
870
650
‐
850
Power
input
of
Fan
W
80
200
Noise
level(10m)
dB(A)
36
‐
42
37
‐
42
37
‐
43
39
‐
45
40
‐
46
Noise
level(1m)
dB(A)
44
‐
51
45
‐
52
45
‐
52
46
‐
54
47
‐
56
Refrigerant
R32
*
Dimension/
Weight
Net
weight
kg
52
54
56
68
78
Gross
weight
kg
64
66
68
73
83
Net
dimension
mm
935*360*545
1045*410*695
Packing
dimension
mm
1060*380*595
1140*430*835
*
Above
data
is
subject
to
update
without
prior
notice.
Summary of Contents for 5
Page 8: ...7 2 Wymiary mm Model Inverter 5 Inverter 7 Inverter 10 Model Inverter 13 Inverter 18 ...
Page 31: ...30 ...
Page 35: ...34 Naciśnij i przytrzymaj przez 5 sekund aż zacznie migać ...
Page 45: ...44 2 Dimension mm Model Inverter 5 Inverter 7 Inverter 10 Model Inverter 13 Inverter 18 ...
Page 70: ...69 3 Opertion of Alsova Pro APP Press and hold 5 second until is flashing ...
Page 80: ...79 Model Inverter 13 Inverter 18 ...
Page 107: ...10 3 Die Hauptschnittstelle Wechselrichter 5 Sekunden gedrückt halten bis blinkt ...
Page 111: ...110 überprüfen ...
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ...A0111HYIELR3204 ...