Troubleshooting,
water
pump
conection
7.1
Error
code
display
on
wire
controller
Error
Code
Malfunction
Reason
Solution
EE
01
High
pressure
failure
TS4
1.
Ambient
temperature
is
too
high
2.
Water
temperature
is
too
high
3.
Water
flow
is
too
low
4.
Fan
motor
speed
is
abnormal
or
fan
motor
is
damaged
under
cooling
mode
5.
Gas
system
jammed
6.
High
pressure
wire
is
loose
or
damaged
7.
Too
much
refrigerant
1.
Choose
the
silent
mode.
2.
Check
the
water
flow
or
filtration
pump
3.
Check
the
fan
motor
under
cooling
mode,
replace
a
new
one
if
it
is
abnormal.
4.
Check
and
repair
the
refrigerating
system
5.
Reconnect
the
high
pressure
wire
or
replace
a
new
high
pressure
switch
6.
Check
and
repair
the
refrigerating
system
EE
02
Low
pressure
failure
TS5
1.
EEV
has
blocked
or
pipe
system
is
jammed
2.
Fan
motor
speed
is
abnormal
or
fan
motor
is
damaged
under
heating
mode
3.
Gas
leakage
4.
Low
pressure
wire
is
loose
or
damaged
1.Check
the
EEV
and
piping
system
Check
the
motor
2.
Check
the
fan
motor
under
heating
mode,
replace
a
new
one
if
it
is
abnormal
3.
Check
refrigeration
system
or
check
the
pressure
value
through
the
high
‐
pressure
gauge.
4.
Reconnect
the
low
pressure
wire
or
replace
a
new
low
pressure
switch
EE
03
or
‘ON’
Water
flow
failure
TS1
1.
The
wiring
of
water
flow
switch
is
loose
or
water
flow
switch
damaged
2.
No/Insufficient
water
flow.
1.
Check
the
wiring
of
water
flow
switch
or
change
a
new
one.
2.
Check
the
filtration
pump
or
the
waterway
system
if
there
is
air
or
jammed
inside
EE
04
Over
heating
protection
for
water
temperature
(d2
‐
TH5)
in
heating
mode
1.
Low
water
flow
2.
Water
flow
switch
is
stuck
and
the
water
supply
stops
3.
TH5
outlet
water
temperature
sensor
is
abnormal
4.
The
difference
of
outlet
water
temperature
and
set
temperature
is
7
℃
or
above
in
heating
mode
1.
Check
the
water
flow
switch
if
it
works
well
2.
Check
the
filtration
pump
or
the
waterway
system
if
there
is
air
or
jammed
inside
3.
Check
TH5
outlet
water
temperature
sensor
or
replace
a
new
one.
4.
Change
the
set
temperature.
EE
05
d6
‐
TH3
Exhaust
too
high
protection
1.
Lack
of
gas
2.
Low
water
flow
3.
Piping
system
has
been
blocked
4.
Exhaust
temp.
sensor
failure
d6
‐
TH3
1.
5.
Ambient
temperature
is
too
high
1.
Check
the
pressure
gauge,
and
fill
with
some
gas
if
it
is
lack
of
gas
2.
Check
the
filtration
pump
or
the
waterway
system
if
there
is
air
or
jammed
inside
3.
Check
the
piping
system
if
there
was
Summary of Contents for 5
Page 8: ...7 2 Wymiary mm Model Inverter 5 Inverter 7 Inverter 10 Model Inverter 13 Inverter 18 ...
Page 31: ...30 ...
Page 35: ...34 Naciśnij i przytrzymaj przez 5 sekund aż zacznie migać ...
Page 45: ...44 2 Dimension mm Model Inverter 5 Inverter 7 Inverter 10 Model Inverter 13 Inverter 18 ...
Page 70: ...69 3 Opertion of Alsova Pro APP Press and hold 5 second until is flashing ...
Page 80: ...79 Model Inverter 13 Inverter 18 ...
Page 107: ...10 3 Die Hauptschnittstelle Wechselrichter 5 Sekunden gedrückt halten bis blinkt ...
Page 111: ...110 überprüfen ...
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ...A0111HYIELR3204 ...