FAM Set-up and Connection
FAM 25/45/60/75/95
en(us)
Page 43/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Connecting the inlet (IN)
The suction pressure at the FAM inlet must be in the range of -0.2 … 1 bar.
Use a negative pressure-resistant, flexible hose or a pipe for the suction-side
connection.
Make sure that the cross-section of the connected hoses/piping is at least as large
as the cross-section of the inlet/outlet port sizes. For the cross-section of the
connection line, use at least DN50 on FAM 75 and 95.
The shape of the tank connection should be set up in such a way that it will always
be lower than the level of the oil in the tank.
NOTICE
Severe contamination
The FAM will be damaged
►
Do not prime directly at the bottom of the tank.
►
Do not prime in the sump.
►
Never prime without a built-in suction screen.
The greatest contamination is found on the bottom of the tank. All
impurities and other particles are deposited on the bottom of the tank.
Connect outlet (OUT)
Take care to ensure that the maximum pressure of 2 bar is not exceeded at the
outlet.
NOTICE
OUT connection closed off
The FAM will be damaged
►
Check to be sure that all of the locking fixtures at the outlet are in "open"
position each time before start-up.
To prevent air from entering the medium, make sure that the pressure
hose with lance is always below the oil level in operation.