4.
Carefully remove the cooler insert by rotating it.
Apply compressed air to free the insert of coarse
contamination.
Place the insert into a cleaning bath with hot
water (temperature 60–65°C) and 5%
VacuCleaner for around 45 minutes.
Example: 10 l water + 0.5 l VacuCleaner.
Afterwards, rinse out the insert with clear water.
Blow it out with compressed air.
Clean the cooler housing.
5.
Mount the new O-rings. Lubricate them lightly for
this purpose.
6.
Perform the assembly in reversed order of
sequence.
7.
Mount the cover plate.
8.
Cleaning the condensation cooler is complete.
Check to see if there are any leaks in the vacuum
pump after switching device back on.