34. Oil pan too full -> drain oil pan and seal leak
Cause:
The float switch in the tray was actuated.
The message appears on the display after 1.8 seconds, and
the FAM switches itself off.
Remedy:
Perform the following steps:
Step
Description
1. Message:
34. Oil pan too full -> drain oil pan and seal leak.
2.
Empty the oil pan on the FAM.
3.
Check the FAM for any leaks and eliminate any that are found.
4.
Actuate ESC key and reset failure with the F3 key.
5.
Restart the FAM by pressing the F1 key.
->a. The fault is repeated.
-> proceed to Step 7.
6.
->b. The fault is not repeated.
-> proceed to Step 8.
7.
Check the float switch in the oil
pan. See page 116.
Check the supply line to the float
switch. If necessary, replace them.
-> proceed to Step 4.
8.
The fault is repaired.