The FAM operates until both specified nominal
values have been reached (see page 65 / 67).
Afterwards, the FAM switches off. Now the
recurrent inspection interval starts (time until the
FAM switches on again, see page 79). After this
has run through, the FAM switches on
automatically once again and runs for at least 2
minutes. If the Relative Humidity is reached once
again after this time, then the FAM will switch off
once again and the recurrent inspection interval
runs again.
FT
= Filtration
The fluid will only be filtered.
FT+H
= Filtration and
Heating
The fluid will be simultaneously filtered and
heated up to the prescribed temperature (see
page 66). Vacuum pump remains switched off.
EW+FTB
= D
Filter to
The fluid will be simultaneously dewatered and
filtered.
The FAM operates until a specified cleanliness
code has been reached (see page 67).
Afterwards, the FAM switches off. Now the
recurrent inspection interval starts (time until the
unit switches on again, see page 79). After this
has run through, the FAM switches on
automatically once again and runs for at least
~ 2 minutes. If the cleanliness code is reached
once again after this time, then the FAM will
switch off once again and the recurrent inspection
interval runs again.
EW+H+FTB
= D
Heat + Filter
to
The fluid will be simultaneously dewatered and
filtered and heated up to the prescribed
temperature (see page 66).
The FAM operates until a specified cleanliness
code has been reached (see page 67).
Afterwards, the FAM switches off. Now the
recurrent inspection interval starts (time until the
unit switches on again, see page 79). After this
has run through, the FAM switches on
automatically once again and runs for at least
~ 2 minutes. If the cleanliness code is reached
once again after this time, then the FAM will
switch off once again and the recurrent inspection
interval runs again.
FTT
= Filter to
The fluid will only be filtered. The FAM operates
until a specified cleanliness code has been
reached (see page 67). Afterwards, the FAM
switches off. Now the recurrent inspection interval
starts (time until the unit switches on again, see
page 79). After this has run through, the FAM
switches on automatically once again and runs for
at least ~ 2 minutes. If the cleanliness code is
reached once again after this time, then the FAM
will switch off once again and the recurrent
inspection interval runs again.