Control Panel Basic (SIMATIC PANEL)
FAM 25/45/60/75/95
en(us)
Page 67/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Selection Contamination (CONT.)
MENU1 -> Cont. -> ISO (example, can also be SAE or NAS depending on sensor)
F1
F2
F3
F4
START =
Start
FAM
Display in operating status "Ready for operation" and with the
error message "Water content
≥
90%, measurement with CS
not possible".
STOP =
Stop
FAM
is displayed only in the operating status "Starting phase" and
"Automatic operation"
RESET
= Reset error messages
Is displayed only in the presence of faults
Display :
ISO: Nominal:
= The nominal value can be changed as follows:
4µ channel
= 2 … 25
6µ channel
= 1 … 24
14µ channel
= 0 … 23
ISO: Actual:
= Display of the current contamination at the FAM inlet.
START
MENU1
ISO
tgt:
act:
Ready for operation. Please press Start
STOP RESET
4µ
4µ
6µ
6µ
14µ
14µ
20
18
18
16
15
14