Error messages / troubleshooting
FAM 25/45/60/75/95
en(us)
Page 121/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
2. Flow at FAM inlet has been too low for 5 minutes. Check the FAM inlet.
Cause:
This error can only arise in the starting phase of the FAM,
because it is only during this phase that the corresponding
timer is running. The message appears if the MAX switch
point in the vacuum column is not achieved after 5 minutes
have elapsed.
If this error arises at the time of the first start-up or after
repairs have been made, then it is advisable to fill the filling
pump in advance with ~ ¼ l of oil. To accomplish this, remove
the plug on the AS and then remove the AS by unscrewing it.
The oil is filled in through this opening. The AS and the plug
are mounted once again afterwards in order to restart the
FAM.
Remedy:
Perform the following steps:
Step
Description
1. Message:
2. Flow at FAM inlet has been too low for 5 minutes. Check the FAM
inlet.
2.
Check all of the locking features in the suction line for flow.
3.
Actuate ESC key and reset failure with the F3 key.
4.
Start the unit by pressing the F1 key.
->a. The fault is repeated.
-> proceed to Step 6.
5.
->b. The fault is not repeated.
-> proceed to Step 11.
6.
Clean the suction filter.
Check the hose between suction filter and filling pump.
Check the filling pump for proper functioning.
7.
Actuate ESC key and reset failure with the F3 key.
8.
Start the unit by pressing the F1 key.
->a. The fault is repeated.
-> proceed to Step 10.
9.
->b. The fault is not repeated.
-> proceed to Step 11.
10.
Contact the HYDAC Service Department.
11.
The fault is repaired.