2013-06-13
Recognise / find suction line filter type
The suction line filter series has been optimized. As a result there are different ways
in which to replace the filter element. Both methods are described below:
Old suction line filter - Cleaning / changing the filter element
Switch off the unit at the main switch.
Close the shut-off valve to the inlet.
Undo the lock nut [B] in counterclockwise direction
using a strap wrench.
Rotate until the filter bowl [A] can be removed.
[B]
[A]
Remove the filter bowl [A].
Pull the filter element downwards out of the filter head,
wash it out and clean it using compressed air, or
dispose of the filter element in an environmentally
correct manner.
Clean the inside of the filter bowl of dirt and any other
matter.
Moisten the O-ring on the filter element lightly with
operating medium.
Carefully insert the new filter element onto the element
mount by rotating it slightly while applying pressure to
the element.
Do not use excessive force or a hammer, etc.
Clean the sealing surfaces on the filter head and filter
bowl.
Check the O-ring for damage. Replace it if necessary.
Moisten the O-ring with the operating medium.
Apply some lubricant to the thread prior to installation.
We recommend for this purpose -> a lubricant