background image

 

PAGE 1

WARNINGS

DO NOT REPLACE ANY ITEM ON FILTER WHILE IT IS PRESSURIZED.
DO NOT OPERATE A LEAKING FILTER. TAKE FILTER OUT OF SERVICE IMMEDIATELY.
DO NOT OPERATE ABOVE MAXIMUM WORKING PRESSURE (MWP) AT MAXIMUM OPERATING TEMPERATURE (°F).

(COALESCING)

IN/OUT

(PARTICULATE)

OUT/IN

November 2016

P/N 432-10016-E

FILTER DETAILS

FLOW DIRECTION THROUGH ELEMENT

OUTLET 

INLET 

OUTLET

 

INLET

 

FILTER

BOWL

FILTER

HEAD

ELEMENT 

SUPPORT

ELEMENT

INLET/

OUTLET

PD-6 POP-UP 

INDICATOR

(STANDARD)

THRU-BOLT 

HOLES

BLANKING 

PLATE

PRODUCT PURPOSE & FUNCTION:

 

Van Air's F200 series filters are designed to remove contaminants from compressed air systems.   Available in 1/4" to 3" 

connection sizes and flow capacities from 15 to 1600 SCFM (at 100 psig) in 16 housings and 9 filtration grades, the F200 series can 

remove oil aerosols, oil vapors, water and particulates.  Housings are made of cast aluminum. They are E-coated and epoxy powder 

coated for corrosion resistance. All units include push-on elements with durable polyester drain layer (except RD grade). 

Accessories include differential pressure indicators, wall mounting kits, connector kits, and automatic drain valves.

OPERATING CONDITIONS

MAXIMUM WORKING PRESSURE

All Models

OPERATING TEMPERATURE

Minimum
Maximum

MAXIMUM RECOMMENDED INLET  

TEMPERATURE

AA, A, RAA, RA, RB, and RC Series

B Series

C Series

RD Series

250 PSIG

35°F

225°F

225°F

175°F

125°F

80°F

ADM-2-2

(OPTIONAL)

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTION

F200 SERIES

COMPRESSED AIR FILTERS

FILTRATION GRADES

APPLICATION

ELEMENT 

GRADE

PURPOSE

NOMINAL 

PARTICULE 

REMOVAL

ELEMENT 

FLOW 

DIRECTION

COLOR 

CODE

OIL 

REMOVAL

(LIQUIDS)

AA

Extra Coarse

Coalescing

25.00 μ

IN/OUT

WHITE

A

Coarse

Coalescing

5.00 μ

IN/OUT

GREEN

B

General Purpose

Coalescing

 1.00 μ

IN/OUT

RED

C

High Efficiency

Coalescing

0.01 μ

IN/OUT

BLUE

PARTICULATE

REMOVAL

(SOLIDS)

RAA

Extra Coarse

Particulate

25.00 μ

OUT/IN

WHITE

RA

Coarse

Particulate

5.00 μ

OUT/IN

GREEN

RB

General Purpose

Particulate

1.00 μ

OUT/IN

RED

RC

High Efficiency

Particulate

0.01 μ

OUT/IN

BLUE

OIL VAPOR

REMOVAL

RD

Vapor Adsorbing

0.01 μ

OUT/IN

WHITE

Summary of Contents for F200-15-1/4

Page 1: ...ll units include push on elements with durable polyester drain layer except RD grade Accessories include differential pressure indicators wall mounting kits connector kits and automatic drain valves OPERATING CONDITIONS MAXIMUM WORKING PRESSURE All Models OPERATING TEMPERATURE Minimum Maximum MAXIMUM RECOMMENDED INLET TEMPERATURE AA A RAA RA RB and RC Series B Series C Series RD Series 250 PSIG 35...

Page 2: ... 5 16 2 1 16 29 3 8 6 9 9 2 3 F200 600 3 600 3 7 7 8 2 3 4 24 1 2 8 19 8 2 7 F200 800 3 800 3 7 7 8 2 3 4 30 1 16 8 21 9 3 6 F200 1000 3 1000 3 7 7 8 2 3 4 34 3 4 12 28 1 4 3 F200 1250 3 1250 3 7 7 8 2 3 4 34 3 4 12 28 1 4 3 F200 1600 3 1600 3 9 2 5 8 42 13 3 4 33 7 4 6 FLOW CAPACITIES AT VARIOUS OPERATING PRESSURES SCFM FILTER MODEL 25 PSIG 50 PSIG 75 PSIG 100 PSIG 125 PSIG 150 PSIG 175 PSIG 200 ...

Page 3: ...lves Remove filter head from the bowl by turning bowl counter clockwise Pull element from locator Set bowl and element aside for use later Install inlet and outlet shutoff valves to facilitate replacement of element Bypass piping is recommended See Figure 1A and 1B MAKE SURE VALVES ARE CLOSED BEFORE PROCEEDING Connect filter head into piping Avoid reducers or bushings to matchinletsize Theresultin...

Page 4: ...4 THRU 25 1 2 A 2 475 01000 4B BODY O RING FOR F200 55 1 2 B 1 475 00146 4C BODY O RING FOR F200 85 3 4 THRU 500 2 B 1 475 00242 4D BODY O RING FOR F200 600 3 THRU 1250 3 C 1 475 00362 4E BODY O RING FOR F200 1600 3 C 1 475 00367 5A 1 4 NPT FILTER HEAD FOR F200 15 1 4 A 1 201 00100 5B 3 8 NPT FILTER HEAD FOR F200 25 3 8 A 1 201 00110 5C 1 2 NPT FILTER HEAD FOR F200 25 1 2 A 1 201 00120 5D 1 2 NPT ...

Page 5: ...0 85 C RC 26 2083 E200 800 C RC 26 10442 E200 85 RD 26 2153 E200 800 RD 26 10444 F200 100 1 E200 100 AA RAA 26 10035 F200 1000 3 E200 1000 AA RAA 26 10040 E200 100 A RA 26 2062 E200 1000 A RA 26 2067 E200 100 B RB 26 2073 E200 1000 B RB 26 2078 E200 100 C RC 26 2084 E200 1000 C RC 26 2089 E200 100 RD 26 2154 E200 1000 RD 26 2159 F200 150 1 E200 150 AA RAA 26 10036 F200 1250 3 E200 1250 AA RAA 26 7...

Page 6: ...4 3 4 2 3 4 1 2 3 4 5 16 MB 3 2 7 1 8 4 15 16 1 3 16 3 15 16 3 8 INSTALLED MOUNTING BRACKET KIT DIMENSIONS TYPE USED ON PART NO A B C D E MB 1 55 84 0720 4 1 2 1 1 4 1 3 4 3 5 16 5 1 4 MB 1 2 15 THRU 25 84 10130 3 3 4 1 1 4 1 3 4 3 4 7 16 MB 2 85 THRU 265 84 0721 5 15 16 1 9 16 2 9 16 4 7 8 6 11 16 MB 2 2 350 THRU 500 84 10131 6 1 2 2 2 3 4 5 1 4 7 5 16 MB 3 2 600 THRU 1250 84 10132 9 5 16 3 3 4 3...

Page 7: ...gh Filter undersized for flow rate Install larger filter Filter grade too fine Install coarser grade element Filter inlet smaller than pipe size Install larger filter Oil carryover Oil present in system before installing filter Clean piping Excessive inlet oil 50ppm Check compressor and or gas oil separator if compressor is rotary vane or screw type Check lube rate if reciprocating compressor Inst...

Page 8: ...ERs DANGER WARNING READ THE OPERATOR S MANUAL BEFORE STARTING OR SERVICING THIS UNIT FAILURE TO ADHERE TO INSTRUCTIONS CAN RESULT IN SEVERE PERSONAL INJURY OR DEATH REPLACEMENT MANUALS CAN BE DOWNLOADED AT www vanairsystems com SAFETY PRECAUTIONS Safety is everybody s business and is based on your use of good common sense All situations or circumstances cannot always be predicted and covered by es...