Performing maintenance
CTU 2xxx series
en-US
Page 69 / 108
BeWa CTU2000 3160738h en-us 2018-11-15.docx
2018-11-15
8.
Carefully press the new filter element
into the element mount by applying slight
pressure, pressing it upwards and
screwing it in.
NOTICE
Do not use a hammer, etc.
9.
(1) Before screwing the union nut back
on, apply a lubricant.
We recommend using white Vaseline as
a lubricant
HYDAC part no. 632391
(2) Screw the filter bowl over the union
nut onto the filter head in a
counterclockwise direction.
When doing this, screw the union nut
hand tight only.
10. Start up the CTU and rinse the inner
chamber using the automatic cleaning
cycle with a volume of 5 ... 10 liters.
11. Check the changed filters for leakage.
12. Close both front doors.
13. The filter element change is now
complete.