Operating the text display TD 200
CTU 2xxx series
en-US
Page 49 / 108
BeWa CTU2000 3160738h en-us 2018-11-15.docx
2018-11-15
Setting the vacuum for suctioning off the rinsing fluid
To set this, proceed as follows:
1.
Switch the shut-off ball valve of the compressed air supply to "on".
2.
To turn on the vacuum generator, press the
button on the text
display.
3.
Set the "VACUUM return line" pressure control valve to 6 bar.
4.
Press the
button on the text display.
5.
The suction vacuum is now set.
Setting the pressure of the rinsing fluid
To set this, proceed as follows:
1.
Switch the shut-off ball valve of the compressed air supply to "on".
2.
Set the pressure control valve to the desired pressure. Check the
pressure shown by the gauge on the operating panel.
3.
The pressure is now set.