Page 19 of 28 – Operation and Maintenance Instructions for Offline Filtration Trolley OFT20 & OFT-HV
Document No: E1412015-1488-M-02
HYDAC Pty Ltd - 109-111 Dohertys Road, Altona North, Victoria 3025, Australia
Telephone: +61 (03) 9272 8900 ; Fax: +61 (03) 9369 8912 ; Website:
Starting up the Unit
Inserting the filter element
The OFT Series is supplied with filter element installed information on changing a filter
element can be found on the next pages.
Priming the pump
If after approximately 30 seconds the unit does not pass any fluid, switch the motor off
and prime the pump. Prime the pump by keeping the suction lance above the height of
the pump and filling the suction hose with oil from a jug/bottle. Switch the pump back on
and quickly return the suction lance into the oil reservoir.
Operation OFT20 & OFT-HV
START THE ELECTRIC MOTOR STOP THE ELECTRIC MOTOR