Page 28 of 28 – Operation and Maintenance Instructions for Offline Filtration Trolley OFT20 & OFT-HV
Document No: E1412015-1488-M-02
HYDAC Pty Ltd - 109-111 Dohertys Road, Altona North, Victoria 3025, Australia
Telephone: +61 (03) 9272 8900 ; Fax: +61 (03) 9369 8912 ; Website:
Technical Specifications OFT-HV
Refer to the type label for specific data of the unit.
Pump Type
Gear Pump
Flow Rate
7 l/min
Operating Pressure
5 bar max.
Element
10µ supplied with unit
Pressure at suction port
0.4 bar abs.
Viscosity range
16 ... 3000 cSt
Permitted operating fluid
Mineral oils
Fluid temperature
0 ... 80°
Ambient temperature
0 ... 45°
Protection class
IP54
Power cable length
2 m
Seal / Gaskets
NBR
Pressure hose (length)
NW 28 with lance (4 m including lance)
Weight
~39 kg without trolley
~47 Kg with trolley
Model Code OFT-HV
OFT HV N 3550 F 010 BF
Offline filtration unit
OFT
Type code
HV = High viscosity
Seals
N
= NBR
Motor output
550 = 0.55 kW
Connection type
F
= 1 x 240V, 50Hz
Filter element
µm = 5, 10 and 20
Clogging indicator
BF = Visual differential indicator