Technical Specifications OFT20
Refer to the type label for specific data of the unit.
Pump Type
Gear Pump
Flow Rate
20 l/min (Viscosity dependant)
Operating Pressure
3.5 bar max.
Element
10µ supplied with unit
Pressure at suction port
0.4 bar abs. (flooded suction
recommended)
Viscosity range
16 ... 200 cSt
Permitted operating fluid
Mineral oils
Fluid temperature
0 ... 80°
Ambient temperature
0 ... 45°
Protection class
IP54
Power cable length
2 m
Seal / Gaskets
NBR
Pressure hose (length)
NW 28 with lance (4 m including lance)
Weight
~22.8 kg without trolley
~32.6 Kg with trolley
Model Code OFT20
OFT 20 N 3370 F 010 BF
Offline filtration unit
OFT
Type code
20
Seals
N
= NBR
Motor output
370 = 0.37 kW
Connection type
F
= 1 x 240V, 50Hz
Filter element
µm = 3, 5, 10 and 20
Clogging indicator