Performing Maintenance
WARNING
Hydraulic systems are under pressure
Bodily injury
► The hydraulic system must be depressurized
before performing any work on the hydraulic
system.
Maintenance Intervals
D
ail
y
M
on
th
ly
A
nn
ua
ll
y
Visual inspection for leakage and damage
X
Cleaning the suction strainer on the line
X
Changing the filter element (if not already changed)
X
Intervals for Changing the Filter Element
To monitor the degree of contamination in the filtration unit it is equipped with an optical
clogging indicator.
If the clogging indicator is red, the differential pressure is too high, indicating that the
filter element is used up and must be changed. The colour green indicates that the
differential pressure over the filter element is < 2.5 bar for OFT20 and <2 bar for OFT-HV
and filtration will take place.
OFT20
OFT-HV