FCU hydraulic connection
Conducting measurements via the High-Pressure Port (INLET)
NOTICE
Closed or blocked outlet at the connection (OUTLET)
The FCU can be damaged.
►
Never seal the connection OUTLET.
►
Put the free end of the OUTLET return hose into an unpressurized
container.
FCU 2xx0-4
To connect the FCU, proceed as follows:
1. Plug the return-line hose into the OUTLET connector and route it into a
suitable container, e.g. hydraulic tank.
2. Set the change-over valve [A] to the setting INLET.
3. Set the flow rate control valve to a value of 5.
4. Check the system pressure. Ensure that this does not exceed a
pressure of 350 bar.
5. Connect the high pressure hose to the INLET connection.
6. Now connect the other end of the high pressure hose to the system.
Oil can start to flow through the FCU as soon as the system
has been connected to the pressure fitting FCU.