CoreLink
TM
P/N 3128012_A
33
CoreLink
™
Case Controller
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
5.10
System parameters, C0: More: Output – SysD
E2 system parameters can be accessed in this Tab.
•
Navigate to C0: More and to Output – SysD 1Read/Write,16 Read variables of Valve
num, SH temp, Valve output, and other E2 parameters as given below.
E2 Parameter
Description
CONTROLTEMP
Control temperature for refrigeration
DEFROSTTERMTEMP
Defrost termination temperature
NUM_OF_VALVES
Number of valves preset in the case
SH_SECTION1
Superheat temperature coil 1
SH_SECTION2
Superheat temperature coil 2
SH_SECTION3
Superheat temperature coil 3
VALVEOUTPUT1
Direct output EEV driver valve 1
VALVEOUTPUT2
Direct output EEV driver valve 2
VALVEOUTPUT3
Direct output EEV driver valve 3
HSVD30_ONLINE
XEV30K Online
HSVD20_1_ONLINE
XEV20Online_1
HSVD20_2_ONLINE
XEV20Online_2
GLB_MAJ_BLD
Major Build code
GLB_MIN_BLD
Minor Build Code
GLB_REV_INFO
Revision information
CTRL STATUS
CL_STATUS