If the welding unit recognizes a problem that cannot be cleared
while printing or data transfer is in progress, it does not resume
printing or transfer and displays a “Printing interrupted” error
message.
8.6 Data Tranfer to a USB Stick
Transferring welding reports to a USB stick is analogous to printing them
off on paper with a PCL-compatible USB printer. Instead of the USB cable
of a printer, stick the USB stick into the USB A interface at the front of
the welding unit, then wait for all the selected reports to print off and the
“Printing finished” message to appear on the screen.
8.7 Data Transfer to a PC with Hürner DataWork
Hürner’s welding data management application DataWork können allows
downloading welding reports from a welding unit directly into the data-
base on a PC. To do so, connect a USB cable from the PC to the USB B
interface at the back of the welding unit. The launch the database appli-
cation Hürner DataWork and, in the
Transfer
menu, select the
Welding
Unit --> PC
option and in its sub-menu,
USB-Port
. See the DataWork
user’s manual for further information on direct download of welding data
to the DataWork database.
When data transfer is completed, an “OK” button appears on the PC
screen, and the welding unit displays a “Printing finished” message.
8.8 Deleting Data in Memory
The report data in memory can be deleted only if all reporting protocols
were already printed. When printing is finished, a “Printing finished” mes-
sage indicates this. When the printer cable is unplugged or the USB stick
is removed, a “Delete Memory” message is displayed. When the START
key is pressed here, a further confirmation message “Delete Memory,
sure?” is shown, which has to be confirmed by pressing the START key
once again. For optimum data integrity, the operator code has to be
read now with the scanning pen. Then, the report data in memory is
deleted.
Important
For every data printing or transfer, always be sure to wait until
the display shows the “Printing finished” message before you
disconnect the printer, PC, or USB stick from the unit. If you
disconnect it too early, the welding unit may ask you whether you
want to delete the data in memory, although the reports were
not properly transferred or printed. In this case, if you delete the
contents of the report memory, the welding reports would be
irrevocably lost and would not have been saved elsewhere.
8.9 Not Deleting Data in Memory
When the printer cable is unplugged, a “Delete Memory” message is
displayed. Press the STOP/RESET key to keep the current report data
in memory. They can then be printed off once again.
9
Unit-Specific Information
9.1 Available Welding Reports
The number of currently free, available welding reports is displayed by
holding down the
ð
key while “Enter Fitting Code” is showing.