Version January 2009
EN
13
HST300 User’s Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str.
35325 Mücke, Germany
Note:
Fitting manufacturers also call the Second Fitting Code “Fitting Trace-
ability Code” or “Tracing Code.”
6.8 Entering Pipe Codes
If the ISO data feature is enabled in the system set-up, after the second
fitting code was entered, “Enter 1
st
Pipe Code” is displayed (see Dis-
play 15).
This numeric input is entered either from a bar code using the scanning
pen or manually using the arrow keys
ñ
,
ò
,
ï
,
ð
. Press the START key
to confirm your input. If the code entered is not correct, a “Code Error”
message appears; check the string of numbers and correct as needed.
If the code entered is correct, it is saved to system memory and inserted
into the welding reports to be printed. By pressing the STOP/RESET key,
you skip this input.
After the First Pipe Code was entered, you have the possibility to enter
a Second Pipe Code. The procedure is the same.
7
Manual Input of Welding Parameters
The fitting has to be connected to the welding unit with the welding cable.
If the manual input feature is enabled in the system set-up, it can be
accessed by pressing the
ò
arrow key. The screen will show a menu as
reproduced in Display 16.
Using the arrow keys
ñ
and
ò
you can select “Enter Numeric Series” (i.e.,
the ordered string of numbers that represents the fitting code) or “Enter
Voltage/Time.” Confirm your selection by pressing the START key.
7.1 Entering the String of Numbers
If this option was chosen in the manual input menu, the “Enter Numeric
Series” display shows. The 24 characters that represent the fitting code
to be entered display as asterisks (
*
). Use the alphanumeric keys to
enter the code. By pressing the START key, you confirm your input which
will then be decoded. If the code entered is not correct, a “Code Error”
message appears; check the string of numbers and correct as needed. If
the code entered is correct, the decoded information is displayed, and the
“Start ?” message indicates that the device is ready to start welding.
7.2 Entering Voltage/Time
If the “Enter Voltage/Time” option was chosen in the manual input menu,
a screen like Display 17 appears on the screen. Use the alphanumeric
keys to set the voltage and the time for the welding process according to
the fitting manufacturer’s instructions, then press START to confirm. The
“Start ?” message indicates that the device is ready to start welding.
8
Printing the Reports
Interfaces
USB A Interface
(at the front of the unit)
for connecting USB printers and USB mass storage media (such as
a USB stick)
USB B Interface
(at the back of the unit)
for connecting the welding unit directly to a PC
Display 17
Display 16
Display 15
Enter 1. Pipe Code
********************
********************
** MANUAL INPUT **
>Enter Numer. Series
Enter Voltage/Time
Manual Input
U= 40 V t= 1000 s