HUAWEI VP9660
Quick Start Guide
3 First Time Use
Issue 04 (2013-12-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
34
Indicator
Status
Description
Off
The board is not being used or it is the standby
board.
ALM
Off
The board is operating correctly.
Steady red or quickly
blinking
The board is malfunctioning.
RUN
Steady green
The board is powered on but is
malfunctioning.
Off
The board is not powered on or the board fails
to start.
Slowly blinking (about
0.5 Hz, once every 2
seconds)
The board is operating correctly according to
the configuration.
Quickly blinking
(about 4 Hz, four times
per second)
The board is loading programs.
GE/FE
Steady green
The network port connection is normal.
Green off
No connection is established on the network
port or the connection fails.
Blinking orange
Data is being received or sent through the
network port.
Orange off
No data is being received or sent through the
network port.
The media and ISDN boards do not provide the ACT indicator. The other indicators listed in
are the same as the indicators on these two types of boards.
3.2 Logging In to the Web Interface
The VP9660 provides web-based management. Using a computer with an Internet browser,
you can log in to the VP9660 web interface for configuration.
Default Settings
During your first login to the VP9660 web interface, use the default settings listed in
Table 3-4
Default settings
Parameter
Value
IP address of the ECCB board GE0 port
192.168.2.1