4.4.9 Replacing the Direct Ventilation Fan
Prerequisites
You have obtained the cabinet door key, and maintenance tool box.
The new fan is intact.
Procedure
Step 1
Switch the corresponding circuit breaker on the direct ventilation fan to OFF.
Step 2
Record the positions where the direct ventilation fan connects to all cables, and then
disconnect terminals corresponding to the cables on the control board.
Step 3
Remove the direct ventilation fan, as shown in Figure 4-17.
Figure 4-17
Removing the direct ventilation fan
Step 4
Install a new fan.
Step 5
Connect the cables and bind the cable ties properly.
Step 6
Power on the module to check whether the alarm is cleared.