28
Description / Part #
Gas Valve: 7855P-034
Check Point
(Main PCB)
CN9
Function
Negative gas valve controls the regulation of gas and air imixture in the
combustion system
Failure Event
① Gas leakage occurs
② Gas valve does not operate (Unable to open/close)
③ Gas flow is not modulated (Proportional gas valve)
Effects
① Spark is not generated.
② Operation of product is stopped
③ Carbon monoxide exceeding the reference is discharged
Error Code
Er 11
Diagonostic
① Check wiring for proper connection
② Check the connection and mounting location
③ Check resistance using a multi-meter
Color / Wire Number
Gas valve (purple) : connector ⑥, ⑫
ⓐ
ⓑ
ⓒ
ⓓ
ⓔ
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
Chapter 2 Components description
CN9
LP-528 REV. 8.01.14
Summary of Contents for EFTC-140F
Page 3: ...1 LP 528 REV 8 01 14 ...
Page 13: ...11 Operation flow chart Chapter 1 Product Characteristics LP 528 REV 8 01 14 ...
Page 14: ...12 Operation flow chart Chapter 1 Product Characteristics LP 528 REV 8 01 14 ...
Page 15: ...13 Wiring Diagram Chapter 1 Product Characteristics LP 528 REV 8 01 14 ...
Page 16: ...14 Wiring Diagram Chapter 1 Product Characteristics Mixing Valve LP 528 REV 8 01 14 ...
Page 42: ...40 Chapter 3 How to use control panel LP 528 REV 8 01 14 ...
Page 67: ...65 Chapter 4 Troubleshooting 1 Flame Detection LP 528 REV 8 01 14 ...
Page 70: ...68 Error code Chapter 4 Troubleshooting LP 528 REV 8 01 14 ...
Page 71: ...69 Chapter 4 Troubleshooting LP 528 REV 8 01 14 ...
Page 72: ...70 Chapter 4 Troubleshooting LP 528 REV 8 01 14 ...
Page 106: ...104 1 Cabinet Replacement Parts Chapter 7 Repair Part Diagram LP 528 REV 8 01 14 ...
Page 107: ...105 Chapter 7 Repair Part Diagram LP 528 REV 8 01 14 ...
Page 108: ...106 2 Combustion System Replacement Parts Chapter 6 Repair Parts Diagram LP 528 REV 8 01 14 ...
Page 109: ...107 Chapter 7 Repair Part Diagram LP 528 REV 8 01 14 ...
Page 110: ...108 Memo LP 528 REV 8 01 14 ...
Page 111: ...109 Memo LP 528 REV 8 01 14 ...
Page 112: ...110 Memo LP 528 REV 8 01 14 ...