polling interval by issuing the appropriate command-line option provided by iSUT. Performs inventory
on target servers, stages deployment, deploys updates, and then reboots the servers.
•
iLO 5 with integrated Smart Update
(Gen10 servers only): Performs iLO Repository-based updates
by downloading the components from iLO Repository when iLO Installation Queue has the
components which can be updated by iSUT.
•
iLO Amplifier Pack
: Displays available updates for servers. Communicates with iSUT (or SUT 1.x) to
initiate updates using the iLO Redfish interface. iSUT reports the status of updates to iLO Amplifier
Pack via iLO Restful Interface.
•
SPP
: A comprehensive systems software and firmware update solution, which is delivered as a single
ISO image.
•
SUM
: A tool for firmware and driver maintenance for HPE ProLiant servers and associated options.
NOTE:
SUM and iLO Amplifier Pack should not manage the same nodes.
Updating firmware from the System Utilities
Use the
Firmware Updates
option to update firmware components in the system, including the system
BIOS, NICs, and storage cards.
Procedure
1.
Access the System ROM Flash Binary component for your server from the Hewlett Packard Enterprise
Support Center.
2.
Copy the binary file to a USB media or iLO virtual media.
3.
Attach the media to the server.
4.
Launch the
System Utilities
, and select
Embedded Applications
>
Firmware Update
.
5.
Select a device.
The
Firmware Updates
screen lists details about your selected device, including the current firmware
version in use.
6.
Select
Select Firmware File
.
7.
Select the flash file in the
File Explorer
list.
The firmware file is loaded and the
Firmware Updates
screen lists details of the file in the
Selected
firmware file
field.
8.
Select
Image Description
, and then select a firmware image.
A device can have multiple firmware images.
9.
Select
Start firmware update
.
Updating the firmware from the UEFI Embedded Shell
Procedure
1.
Access the System ROM Flash Binary component for your server from the Hewlett Packard Enterprise
Support Center (
http://www.hpe.com/support/hpesc
).
2.
Copy the binary file to a USB media or iLO virtual media.
3.
Attach the media to the server.
156
Software and configuration utilities
Summary of Contents for ProLiant DL180
Page 30: ...24 bay SFF hot plug drive model Fan bay numbering 30 Component identification...
Page 58: ...SFF 4 Install the drive LFF SFF 58 Hardware options installation...
Page 97: ...Secondary riser cage Slot 4 Slot 5 or 6 Hardware options installation 97...
Page 128: ...Box 2 to type a controller Box 2 to type p controller 128 Cabling...
Page 129: ...Box 3 to system board Box 3 to type a controller Cabling 129...
Page 130: ...Box 3 to type p controller 8 bay SFF power cable default 130 Cabling...
Page 135: ...Mini SAS cable to SAS expander Cabling 135...
Page 137: ...M 2 SSD enablement board installed in secondary riser Cabling 137...
Page 142: ...Cable routing Serial port Cable routing iLO Service Port SFF LFF 142 Cabling...
Page 144: ...Secondary riser cage Slot 4 Slot 5 or 6 144 Cabling...